AG-309.15N

AG-309.15N – Cable and metal-pipe locator

AG-309.15N

AG-309.15N – Cable and metal-pipe locator. High tech device for detection of cables, with direct digital measurement of the current.

Features AG-309.15N:

  • Firstly, monoblock AP-019 digital receiver
  • Secondly, 20W AG-105 transmitter
  • Moreover, high precession location of armoured OFC upto 10 M
  • In addition, direct digital measurement of cable current
  • In conclusion, direct digital depth measurement up to 10 m.

Brief description AG-309.15N:

  • Firstly, three modes of operation : “ROUTE”, “GRAPHIC”, “FRIEND-OR-FOE”
  • Secondly, three inbuilt sensors make omnidirectional antenna showing a direction of a cable on LCD
  • Moreover, inbuilt sensor for digital measurement of the depth and current
  • In addition, measured depth is 10 m
  • Meanwhile, passive frequency: Power, Radio, BB
  • Most importantly, active frequency: 512/1024/8192/32768 Hz
  • However, sensitivity : 100μA
  • Likewise, large LCD display with high resolution and adjustable backlight brightness
  • After that, transmitter – 20W
  • And in conclusion, cast body, the case is sealed along the entire length to the connectors

Application:

  • To sum up, detection of cable under ground upto 10 M

Specifications AG-309.15N

Receiver AP-019.1 Specifications

ParameterValue
Quasi-resonant frequencies of the filter50(60)/ 100(120)/ 512/ 1024/ 8192 / 32768 Hz
Quasiresonant filter quality factor (Q)Not less than 100
Frequency range “Broad band”0,04 to 8 kHz
Frequency range “Radio”8 to 40 kHz
The maximum gain of the electric path>100 dB
Number of built-in sensors4
Connected external sensorsKI-110, HP-117, DODK-117, DKI-117 (made by «TECHNO-AC»)
Sensitivity controlAuto – for 2D display «Route». Semi-automatic or manual (optional) – for the «Graphics». Automatic or manual (optional) – for the «2F» mode.
Determination the burial depth of the routeAutomatically in the mode Route 0 to 9,99 m
The accuracy of determining of the depth±5%
Measurement of the current of the signal receivedAutomatically in the mode Route 0.001 to 9,99 A
Accuracy of the measurement of the current of the signal received±5%
Support of energy saving (intermittent) modes of the route locating generatorsAt combined work with the route locating generators made by “TECHNO-AC” (“Pulse” mode)
Visual indicationLCD display, 320×240 pix., LED lighting
Induced parameters

– parameters of setting and control

– 2D visualization of the route location relative to the device

– graphics of the signal level from sensors

– route burial depth

– signal current

Audio indication Built-in transmitter – synthesized sound HM- sound indication of buttons pressing
Power supply source4 to 7 V (4 elements of C type)
Time of continuous work from the one complete of the alkaline batteriesNot less than 20 hours
Temperature range for storage / operation-30 to 60°С / -20 to 60°С
House protection degreeIP54
Dimensions330x140x700 mm
Weight2,1 kg

Transmitter AG-105 Technical specifications

The frequencies of the continuous «Co» or pulse «Pu» signal, Hz ± 0,1% – «kHz»
Load «clips» or «clamp»512 – «0.5» / 1024 – «1.0» / 8192 – «8.2» / 32768 – «33»
«Antenna» modes8192 – «8.2» / 32768 – «33»
Operating modes
«Antenna» modesInternal transmitting inductor «In».
External induction transmitting antenna «An».
«Modulation» modes (special form signal)Pulse «Pu» (short-term transmissions of the sine signals). Transmission duration 0,12sec. Transmissions repetition frequency 1Hz.
Dual-frequency «2F» (simultaneous frequency generation 1024Hz, 8192Hz). Amplitudes ratio 4/1 (respectively).
Output parameters under power supply voltage 12 to 15V
Output current, А
Restricted by the program under manual increment, – at frequency 512Hz «0.5» / 1024Hz «1.0» / 8192Hz «8.2» / «2F»
– at frequency 32768Hz «33»
Set by the program for automatic adjustment with the external load of «clips» or «clamp», ≥0,2 – at frequency 512Hz «0.5» / 1024Hz «1.0» / «2F»
0,1 – at frequency 8192Hz «8.2» / 32768Hz «33»
Maximum output voltage, V
Depending on «modulation», ≥32 – in the dual-frequency modulation mode «2F»
40 – in other modes
Maximum output power, W
Restricted by the program, ≥20 – In the continuous «Co» and pulse «Pu» modes at frequencies 512Hz «0.5» / 1024Hz «1.0» / 8192Hz «8.2» at load resistance up to 80Ω In dual-frequency mode «2F» at load resistance up to 50Ω.
– At frequency 32768Hz «33» at load resistance up to 260Ω.
Power supply sources
Operating range of the supply voltagesMinimally acceptable voltage for oscillation start-up – 7V.
Maximum allowed voltage for operation – 15V.
Automatic shutdown voltage in the “oscillation” mode < 4,2V.
Battery set8 «alkaline» cells 1,5V «type С» Recommended – «Duracell ® ULTRA».
External power supply sources (optional)Battery «12V» (e.g. automotive) Output voltage 11 to 14V, maximum current not less than 4А.
Mains power supply adapter АG114М.02.020 (extra accessory based on GS60A15-P1J «MEAN WELL») Output voltage 15V, power 60W.
Operating time («life cycle»)While in operation of the battery set «type Сх8» is defined by the quality (capacity and «load capability») of the applied alkaline cells and can be equal to from 4 to 6 hours in the «Co» и «2F» modes or from 20 to 30 hours in the «Pu» mode at initial output voltage 7W in «continuous» modes «Co» / «2F» or at initial output voltage 15W in pulse modulation mode «Pu».
Under the external power supply is fully conditioned by this external energy source characteristics therefore under mains supply operating time is unlimited.

Operational characteristics

An automatic control over the output voltage during oscillation processProportional control over the output power depending on the “energy potential” of the power supply source.
Automatic shutdowns of the device1. At power supply voltage in the “stop” mode < 6,5V.
2. At power supply voltage in the “oscillation” mode < 4,2V.
3. At power supply voltage > 15,5V.
4. In case of exceeding of the admissible absorbed current value (the exact figure depends on the actual mode).
5. In case of short circuit of the output during the adjustment process (actuation of the hardware safety system of the terminal amplifier).
6. In case of non-compliance of the oscillation mode settings depending on whether the external antenna is installed in the output or not (the switch to the “stop” mode).
7. In case of “long” (≈ 100sec) downtime in the “stop” mode (if the buttons are not pushed).
Adjustment with loadAutomatic, up to the reaching of the specific consumption rate or attainment of the load current: – ≥ 0,2А at frequencies 512Hz «0.5» / 1024Hz «1.0» / «2F»; – ≥ 0,1А at frequencies 8192Hz «8.2» и 32768Hz «33».
Manual after the automatic adjustment.
Connection options to the utility under examination1. «Contact» connection with “earth return”.
2. «Non-contact» connection with application of the internal transmitting antenna «In».
3. «Non-contact» connection with the use of external induction transmitting antenna «An» (the emission intensity is higher and easier access to the utility in comparison with the internal transmitting antenna «In»).
4. «Non-contact» connection using the transmitting induction “clamp” (selection of the cable from the bunch is possible).
Structural parameters
Power output amplifierThe technology — updated CLASS D Efficiency to 85%.
LED indicatorsSeparate light-emitting diodes indicating parameters and modes.
Digital indicator displaying the modes and parameters values and also showing output parameters of the «MULTIMETER» measurements, e.g.: output voltage (V), load current (А), load power (W) and load resistance (Ω /kΩ).
Overall dimensions of the electronic unit (case), not more than, mm.216х180х105mm
The weight of the electronic unit, not more than, kg2
 
The admissible environment temperatures range when in operation– 30 to +60°С With “battery” power supply it is not recommended to use the device under sub-zero environmental temperatures.
Ingress protection ratingIP65 (when the enclosure-case is shut).

Standard set AG-309.15N

  • Receiver АP-019.1
  • Transmitter АG-105
  • Power connection cable AG120.02.080
  • External power supply cable AG120.02.070
  • Grounding rod
  • Grounding cable
  • Battery alkaline R14 (12pcs.)
  • Contact magnetic
  • Set carrying bag
  • Receiver case
  • Operation manual
  • Technical passport

Fault Location Sensors is not included in the standard kit AG-309.15N

Sensor DKI-117

1. Sensor DKI-117

Sensor DODK-117

2. Sensor DODK-117

Sensor NR-117

3. Sensor NR-117

Clamps CI-105

4. Clamps CI-105

Clamps CI-105/50

5. Clamps CI-105/50

Clamps CI-105/110

6. Clamps CI-105/110

Clamps CI-105/125

7. Clamps CI-105/125

 

Open or Download

 

AG-309.15N

Brochure

AG-309.15N

Brochure

AG-309.15N

Manual

AG-309.15N

Test report

Catalog

Catalog

Video

Video1

Video

Video2

Video

Video3

CBI-309G

CBI-309N

TPT-522N

Dealirship full kit

ATG-435.15N

AG-511N

AG-438.15N

AG-309.15G

Therefore, as a result,so, consequentlyTherefore, as a result,so, consequentlyTherefore, as a result,
That is to say, in other words,to clarifyThat is to say, in other words,to clarifyThat is to say, in other words,
That is to say,in other words,to clarifyThat is to say,in other words,to clarifyThat is to say,in other words,
For example, for instancein additionFor example, for instancein additionFor example, for instance
Above all,most importantly, certainlyAbove all,most importantly, certainlyAbove all,most importantly, 
Firstly/secondly, further, and, moreover, Firstly/secondly, further, and, moreover, Firstly/secondly, further, 
Meanwhile,during, subsequently, Meanwhile,during, subsequently, Meanwhile,during, 
Likewise,similarly,in the same veinLikewise,similarly,in the same veinLikewise,similarly,
Therefore, as a result,so, consequentlyTherefore, as a result,so, consequentlyTherefore, as a result,
That is to say, in other words,to clarifyThat is to say, in other words,to clarifyThat is to say, in other words,
That is to say,in other words,to clarifyThat is to say,in other words,to clarifyThat is to say,in other words,
For example, for instancein additionFor example, for instancein additionFor example, for instance
Above all,most importantly, certainlyAbove all,most importantly, certainlyAbove all,most importantly, 
Firstly/secondly, further, and, moreover, Firstly/secondly, further, and, moreover, Firstly/secondly, further, 
Meanwhile,during, subsequently, Meanwhile,during, subsequently, Meanwhile,during, 
Likewise,similarly,in the same veinLikewise,similarly,in the same veinLikewise,similarly,
Therefore, as a result,so, consequentlyTherefore, as a result,so, consequentlyTherefore, as a result,
That is to say, in other words,to clarifyThat is to say, in other words,to clarifyThat is to say, in other words,
That is to say,in other words,to clarifyThat is to say,in other words,to clarifyThat is to say,in other words,
For example, for instancein additionFor example, for instancein additionFor example, for instance
Above all,most importantly, certainlyAbove all,most importantly, certainlyAbove all,most importantly, 
Firstly/secondly, further, and, moreover, Firstly/secondly, further, and, moreover, Firstly/secondly, further, 
Meanwhile,during, subsequently, Meanwhile,during, subsequently, Meanwhile,during, 
Likewise,similarly,in the same veinLikewise,similarly,in the same veinLikewise,similarly,